Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
1.
Pediatr Cardiol ; 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38727825

RESUMO

This study aimed to evaluate the current state of congenital interventional cardiology training worldwide, with a focus on case volumes, competency assessment, and the need for ongoing mentorship during early career stages. A survey was conducted among program directors (PDs) of congenital interventional training programs across the globe. The survey gathered data on training pathways, case volumes, types of procedures performed, trainee competency assessment, and the role of ongoing mentorship. Of the 79 PDs who completed the survey, it was observed that training pathways and case volumes varied significantly, particularly between the United States and other countries. Most PDs reported an annual laboratory case volume of >500 congenital cardiac cases, with most cases being interventional. While trainees demonstrated competency in simple procedures (diagnostic cases, simple ASD closure), complex interventions (such as patent ductus arteriosus closure in premature infants) require ongoing mentorship for graduates. PDs recommended a minimum case volume of 400 total cases for trainees, including 250 interventional cases. In addition to case volumes, assessing trainee competency was deemed important, with clinical reasoning, judgment, skillset, teamwork, and complication management being key areas of evaluation. The study highlights the variability in congenital interventional cardiology training and the need for ongoing mentorship during the early career years. External mentorship programs, facilitated by national and international societies, are proposed to provide critical support for early career interventionalists thus enhancing patient care for congenital heart disease. Ultimately, the findings of this survey may serve as a framework for future training standards and guidelines in this specialized field.

2.
Circ Cardiovasc Interv ; : e013729, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38666384

RESUMO

BACKGROUND: Transverse aortic arch obstruction is a challenging lesion for which stent implantation provides a potentially important alternate therapy. The objectives were to evaluate the technical, procedural, and medium-to-long-term clinical outcomes of percutaneous stent implantation of transverse aortic arch obstruction. METHODS: This is a retrospective, multicenter study of transverse aortic arch stent implantation. Univariable and multivariable analyses were performed. RESULTS: Index catheterization included 187 stent implants in 146 patients. The median age is 14.3 years (interquartile range, 9.3-19), weight is 53 kg (30-69), and follow-up is 53 months (12-120). The most common stent design was open cell (n=90, 48%). Stents overlapped 142 arch vessels (37 carotid arteries) in 118 (81%) cases. Technical and procedural success rates were 100% and 88%, respectively. Lower weight (P=0.018), body surface area (P=0.013), and minimum-to-descending aortic diameter ratio (P<0.001) were associated with higher baseline aortic gradient. The residual gradient was inversely associated with implant and final dilation diameters (P<0.001). The combined incidence of aortic injury and stent-related complications was 14%. There were no reports of abnormal brain scans or stroke. Blood pressure cuff gradient, echocardiographic arch velocity, and hypertension rates improved within 1-year follow-up with increased antihypertensive medication use. Reintervention was reported in 60 (41%) patients at a median of 84 (22-148) months to first reintervention. On multivariable logistic regression, residual aortic gradient >10 mm Hg was associated with increased odds of reintervention at all time points when controlling for each final dilation diameter, weight, and minimum-to-descending aortic diameter ratio. CONCLUSIONS: Transverse aortic arch stent implantation has high rates of technical, procedural, and medium-to-long-term clinical success. Aortic gradient >10 mm Hg is associated with increased odds of reintervention at 1-year and most recent follow-ups. Open cell stent design was frequently used for its advantages in conformability, perfusion of arch vessels, low fracture rate, and the ability to perform effective angioplasty of side cells.

4.
J Am Coll Cardiol ; 83(1): 63-81, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38171712

RESUMO

Recent years have witnessed exponential growth in cardiac imaging technologies, allowing better visualization of complex cardiac anatomy and improved assessment of physiology. These advances have become increasingly important as more complex surgical and catheter-based procedures are evolving to address the needs of a growing congenital heart disease population. This state-of-the-art review presents advances in echocardiography, cardiac magnetic resonance, cardiac computed tomography, invasive angiography, 3-dimensional modeling, and digital twin technology. The paper also highlights the integration of artificial intelligence with imaging technology. While some techniques are in their infancy and need further refinement, others have found their way into clinical workflow at well-resourced centers. Studies to evaluate the clinical value and cost-effectiveness of these techniques are needed. For techniques that enhance the value of care for congenital heart disease patients, resources will need to be allocated for education and training to promote widespread implementation.


Assuntos
Inteligência Artificial , Cardiopatias Congênitas , Humanos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Ecocardiografia , Técnicas de Imagem Cardíaca/métodos , Imageamento por Ressonância Magnética/métodos
5.
JACC Cardiovasc Interv ; 17(2): 231-244, 2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38267137

RESUMO

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) has expanded and evolved since its initial commercial approval in the United States in 2010. OBJECTIVES: This study sought to characterize real-world practice, including patient selection, procedural outcomes, complications, and off-label usage. METHODS: Characteristics and outcomes for patients undergoing balloon-expandable TPVR were collected from the American College of Cardiology National Cardiovascular Data Registry IMPACT (Improving Pediatric and Adult Congenital Treatment) Registry. RESULTS: Between April 2016 and March 2021, 4,513 TPVR procedures were performed in patients with a median age of 19 years, 57% with a Melody (Medtronic Inc) and 43% with a SAPIEN (Edwards Lifesciences) valve. Most implanting centers performed <10 cases annually. One-third of transcatheter pulmonary valve implants were into homograft conduits, one-third were into bioprosthetic valves (BPVs), 25% were in native or patched right ventricular outflow tracts (RVOTs), and 6% were into Contegra (Medtronic Inc) conduits. Over the course of the study period, SAPIEN valve use grew from ∼25% to 60%, in large part because of implants in patients with a native/patched RVOT. Acute success was achieved in 95% of patients (95.7% in homografts, 96.2% in BPVs, 94.2% in native RVOTs, and 95.4% in Contegra conduits). Major adverse events occurred in 2.4% of procedures, more commonly in patients with a homograft (2.9%) or native RVOT (3.4%) than a prior BPV (1.4%; P = 0.004). CONCLUSIONS: This study describes novel population data on the use and procedural outcomes of TPVR with balloon-expandable valves. Over time, there has been increasing use of TPVR to treat regurgitant native RVOT anatomy, with the SAPIEN valve more commonly used for this application.


Assuntos
Próteses Valvulares Cardíacas , Valva Pulmonar , Substituição da Valva Aórtica Transcateter , Adulto , Humanos , Criança , Adulto Jovem , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Resultado do Tratamento , Sistema de Registros
6.
J Cardiovasc Comput Tomogr ; 18(1): 75-99, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37517984

RESUMO

This consensus document for the performance of Cardiovascular Computed Tomography (CCT) to guide intervention in the right ventricular outflow tract (RVOT) in patients with congenital disease (CHD) was developed collaboratively by pediatric and adult interventionalists, surgeons and cardiac imagers with expertise specific to this patient subset. The document summarizes definitions of RVOT dysfunction as assessed by multi-modality imaging techniques and reviews existing consensus statements and guideline documents pertaining to indications for intervention. In the context of this background information, recommendations for CCT scan acquisition and a standardized approach for reporting prior to surgical or transcatheter pulmonary valve replacement are proposed and presented. It is the first Imaging for Intervention collaboration for CHD patients and encompasses imaging and reporting recommendations prior to both surgical and percutaneous pulmonary valve replacement.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Pulmonar , Cirurgiões , Adulto , Humanos , Criança , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X , Angiografia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/métodos
7.
Ann Biomed Eng ; 52(2): 386-395, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37864043

RESUMO

Congenital heart disease (CHD) accounts for nearly one-third of all congenital defects, and patients often require repeated heart valve replacements throughout their lives, due to failed surgical repairs and lack of durability of bioprosthetic valve implants. This objective of this study is to develop and in vitro test a fetal transcatheter pulmonary valve replacement (FTPVR) using sutureless techniques to attach leaflets, as an option to correct congenital defects such as pulmonary atresia with intact ventricular septum (PA/IVS), in utero. A balloon expandable design was analyzed using computational simulations to identify areas of failure. Five manufactured valves were assembled using the unique sutureless approach and tested in the fetal right heart simulator (FRHS) to evaluate hemodynamic characteristics. Computational simulations showed that the commissural loads on the leaflet material were significantly reduced by changing the attachment techniques. Hemodynamic analysis showed an effective orifice area of 0.08 cm2, a mean transvalvular pressure gradient of 7.52 mmHg, and a regurgitation fraction of 8.42%, calculated over 100 consecutive cardiac cycles. In conclusion, the FTPVR exhibited good hemodynamic characteristics, and studies with biodegradable stent materials are underway.


Assuntos
Próteses Valvulares Cardíacas , Poliésteres , Atresia Pulmonar , Substituição da Valva Aórtica Transcateter , Humanos , Atresia Pulmonar/cirurgia , Coração Fetal , Desenho de Prótese , Valva Aórtica , Resultado do Tratamento
8.
Heart ; 110(7): 491-499, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-37935570

RESUMO

BACKGROUND: Pulmonary hypertension (PH) is a common complication in patients with complete dextro-transposition of the great arteries (TGA) after atrial switch (D-TGA/AS) and congenitally corrected TGA (ccTGA). In this population with subaortic right ventricles (sRVs), echocardiography is a poor screening tool for PH; implantable invasive haemodynamic monitoring (IHM) could be used for this purpose, but data are limited. The aim of this study is to report on novel uses of IHM in patients with sRV. METHODS: This retrospective study describes the uses of IHM, impact of IHM on heart failure hospitalisation (HFH) and device-related complications in adults with sRV from a single centre (2015-2022). RESULTS: IHM was placed in 18 patients with sRV (median age 43 (range 30-54) years, 8 female, 16 with D-TGA/AS, 2 with ccTGA); 16 had moderate or severe sRV systolic dysfunction, 13 had PH on catheterisation. IHM was used for (1) Medical therapy titration, (2) Medical management after ventricular assist device in patients with transplant-limiting PH and (3) Serial monitoring of pulmonary artery pressures without repeat catheterisations to help identify the optimal time for heart transplant referral. In follow-up (median 23 months), HFHs/year were similar to the year prior to IHM (median 0 (IQR 0-1.0) before vs 0 (0-0.8) after, p=0.984). Device migration occurred in one, without long-term sequelae. CONCLUSIONS: Uses of IHM in patients with sRV are described which may minimise the need for serial catheterisations in a population where PH is prevalent. HFHs were low overall but not impacted by IHM. One device-related complication occurred without long-term consequence.


Assuntos
Monitorização Hemodinâmica , Transposição dos Grandes Vasos , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Ventrículos do Coração , Transposição das Grandes Artérias Corrigida Congenitamente
10.
J Am Heart Assoc ; 12(24): e031836, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38063189

RESUMO

BACKGROUND: Data on the use of implanted hemodynamic monitoring (IHM) in patients with Fontan circulation are limited. This study reports our experience using the CardioMEMS HF system in adults with Fontan circulation. METHODS AND RESULTS: This single-center, retrospective study evaluated heart failure hospitalizations, procedural complications, and device-related complications in patients with Fontan circulation referred for IHM placement (2015-2022). The association of pulmonary artery pressure (by most recent catheterization and median IHM pressure within 30 days of placement) with both death and follow-up Model for End-Stage Liver Disease Excluding International Normalized Ratio score were evaluated. Of 18 patients referred for IHM placement, 17 were successful (median age, 30 [range 21-48] years, 6 women). Procedural complications (access site hematomas, pulmonary artery staining) occurred in 3 patients, without device-related procedural complications. In follow-up (median, 35 [range, 6-83] months), 1 patient developed a pulmonary embolism (possibly device-related). Heart failure hospitalizations/year were similar before and after IHM (median, 1 [interquartile range, 0-1.0] versus 0.6 [0-2.3]; P=0.268), though only 46% of heart failure hospitalizations had associated IHM transmissions. IHM pressures were associated with Model for End-Stage Liver Disease Excluding International Normalized Ratio scores (R2=0.588, P<0.001), though catheterization pressures were not (R2=0.140, P=0.139). The long-term mortality rate was 53% in this cohort. On unadjusted survival analysis, IHM pressures ≥18 mm Hg were associated with mortality (log rank P=0.041), which was not reproduced with catheterization pressures (log rank P=0.764). CONCLUSIONS: In patients with Fontan circulation, IHM did not reduce heart failure hospitalizations, though patient adherence to transmission was low. Device-related complications were low. IHM pressures may better represent real-life conditions compared with catheterization given associations with mortality and Model for End-Stage Liver Disease Excluding International Normalized Ratio score.


Assuntos
Doença Hepática Terminal , Técnica de Fontan , Cardiopatias Congênitas , Insuficiência Cardíaca , Monitorização Hemodinâmica , Adulto , Humanos , Feminino , Adulto Jovem , Pessoa de Meia-Idade , Técnica de Fontan/efeitos adversos , Estudos Retrospectivos , Índice de Gravidade de Doença , Insuficiência Cardíaca/etiologia , Cardiopatias Congênitas/cirurgia
11.
J Perinatol ; 43(10): 1238-1244, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37587183

RESUMO

OBJECTIVE: This study describes 3-year follow-up of 200 infants weighing ≥ 700 grams who underwent transcatheter patent ductus arteriosus (PDA) closure with the Amplatzer Piccolo™ Occluder. STUDY DESIGN: Between June 2017 and February 2019, 200 children were enrolled in this U.S. study (NCT03055858). PDA closure, survival, and device- or procedure-related events were evaluated. A total of 156 of the available 182 patients (86%) completed the study. RESULTS: The implant success rate was 95.5% (191/200). At 3 years, PDA closure was observed in 100% (33/33) of patients. Survival was >95% with 9 reported deaths. No deaths were adjudicated as device- or procedure-related. Notable events included aortic obstruction (2) requiring stent placement and tricuspid regurgitation (5), for which no interventions were required. CONCLUSIONS: This follow-up study demonstrates high rates of PDA closure, low serious complication rates, and survival > 95% at 3 years. The Amplatzer Piccolo™ Occluder is a safe and effective therapy for PDA treatment in premature infants. CLINICALTRIALS: gov identifier: NCT0305585.


Assuntos
Permeabilidade do Canal Arterial , Dispositivo para Oclusão Septal , Lactente , Humanos , Criança , Seguimentos , Permeabilidade do Canal Arterial/cirurgia , Estudos Prospectivos , Cateterismo Cardíaco/efeitos adversos , Dispositivo para Oclusão Septal/efeitos adversos , Resultado do Tratamento
12.
World J Pediatr Congenit Heart Surg ; 14(6): 761-791, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37647270

RESUMO

This consensus document for the performance of cardiovascular computed tomography (CCT) to guide intervention in the right ventricular outflow tract (RVOT) in patients with congenital heart disease (CHD) was developed collaboratively by pediatric and adult interventionalists, surgeons, and cardiac imagers with expertise specific to this patient subset. The document summarizes definitions of RVOT dysfunction as assessed by multimodality imaging techniques and reviews existing consensus statements and guideline documents pertaining to indications for intervention. In the context of this background information, recommendations for CCT scan acquisition and a standardized approach for reporting prior to surgical or transcatheter pulmonary valve replacement are proposed and presented. It is the first Imaging for Intervention collaboration for CHD patients and encompasses imaging and reporting recommendations prior to both surgical and percutaneous pulmonary valve replacement.


Assuntos
Cardiopatias Congênitas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Obstrução do Fluxo Ventricular Externo , Adulto , Humanos , Criança , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Desenho de Prótese , Cateterismo Cardíaco/métodos , Cardiopatias Congênitas/cirurgia , Tomografia Computadorizada por Raios X , Insuficiência da Valva Pulmonar/cirurgia , Obstrução do Fluxo Ventricular Externo/cirurgia
13.
Pediatr Cardiol ; 44(5): 973-995, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37149833

RESUMO

Patch augmentation of the right ventricular outflow tract (RVOT) and pulmonary artery (PA) arterioplasty are relatively common procedures in the surgical treatment of patients with congenital heart disease. To date, several patch materials have been applied with no agreed upon clinical standard. Each patch type has unique performance characteristics, cost, and availability. There are limited data describing the various advantages and disadvantages of different patch materials. We performed a review of studies describing the clinical performance of various RVOT and PA patch materials and found a limited but growing body of literature. Short-term clinical performance has been reported for a multitude of patch types, but comparisons are limited by inconsistent study design and scarce histologic data. Standard clinical criteria for assessment of patch efficacy and criteria for intervention need to be applied across patch types. The field is progressing with improvements in outcomes due to newer patch technologies focused on reducing antigenicity and promoting neotissue formation which may have the ability to grow, remodel, and repair.


Assuntos
Cardiopatias Congênitas , Tetralogia de Fallot , Obstrução do Fluxo Ventricular Externo , Humanos , Artéria Pulmonar/cirurgia , Obstrução do Fluxo Ventricular Externo/cirurgia , Ventrículos do Coração/cirurgia , Cardiopatias Congênitas/cirurgia , Procedimentos Cirúrgicos Vasculares/métodos , Resultado do Tratamento , Tetralogia de Fallot/cirurgia
14.
J Cardiovasc Comput Tomogr ; 17(3): 211-219, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36868899

RESUMO

BACKGROUND: To promote the rational use of cardiovascular imaging in patients with congenital heart disease, the American College of Cardiology developed Appropriate Use Criteria (AUC), but its clinical application and pre-release benchmarks have not been evaluated. We aimed to evaluate the appropriateness of indications for cardiovascular magnetic resonance (CMR) and cardiovascular computed tomography (CCT) in patients with conotruncal defects and to identify factors associated with maybe or rarely appropriate (M/R) indications. METHODS: Twelve centers each contributed a median of 147 studies performed prior to AUC publication (01/2020) on patients with conotruncal defects. To incorporate patient characteristics and center-level effects, a hierarchical generalized linear mixed model was used. RESULTS: Of the 1753 studies (80% CMR, and 20% CCT), 16% were rated M/R. Center M/R ranged from 4 to 39%. Infants accounted for 8.4% of studies. In multivariable analyses, patient- and study-level factors associated with M/R rating included: age <1 year (OR 1.90 [1.15-3.13]), truncus arteriosus (vs. tetralogy of Fallot, OR 2.55 [1.5-4.35]), and CCT (vs. CMR, OR 2.67 [1.87-3.83]). None of the provider- or center-level factors reached statistical significance in the multivariable model. CONCLUSIONS: Most CMRs and CCTs ordered for the follow-up care of patients with conotruncal defects were rated appropriate. However, there was significant center-level variation in appropriateness ratings. Younger age, CCT, and truncus arteriosus were independently associated with higher odds of M/R rating. These findings could inform future quality improvement initiatives and further exploration of factors resulting in center-level variation.


Assuntos
Cardiopatias Congênitas , Lactente , Humanos , Valor Preditivo dos Testes , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Tomografia Computadorizada por Raios X , Imageamento por Ressonância Magnética
15.
Cardiol Young ; 33(9): 1730-1732, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36924160

RESUMO

We present the first-in-paediatric uses of a mechanical aspiration system for percutaneous removal of right atrial masses in three patients, including central line-related thrombus and metastatic tumour. Percutaneous mechanical removal of right atrial masses can be performed safely and effectively.


Assuntos
Fibrilação Atrial , Cardiopatias , Trombose , Humanos , Criança , Trombectomia , Sucção , Trombose/cirurgia
16.
J Am Soc Echocardiogr ; 36(5): 543-552, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36623710

RESUMO

BACKGROUND: Echocardiographic quantification of fetal cardiac strain is important to evaluate function and the need for intervention, with both two-dimensional (2D) and three-dimensional (3D) strain measurements currently feasible. However, discrepancies between 2D and 3D measurements have been reported, the etiologies of which are unclear. This study sought to determine the etiologies of the differences between 2D and 3D strain measurements. METHODS: A validated cardiac motion-tracking algorithm was used on 3D cine ultrasound images acquired in 26 healthy fetuses. Both 2D and 3D myocardial strain quantifications were performed on each image set for controlled comparisons. Finite element modeling of 2 left ventricle (LV) models with minor geometrical differences were performed with various helix angle configurations for validating image processing results. RESULTS: Three-dimensional longitudinal strain (LS) was significantly lower than 2D LS for the LV free wall and septum but not for the right ventricular (RV) free wall, while 3D circumferential strain (CS) was significantly higher than 2D CS for the LV, RV, and septum. The LS discrepancy was due to 2D long-axis imaging not capturing the out-of-plane motions associated with LV twist, while the CS discrepancy was due to the systolic motion of the heart toward the apex that caused out-of-plane motions in 2D short-axis imaging. A timing mismatch between the occurrences of peak longitudinal and circumferential dimensions caused a deviation in zero-strain referencing between 2D and 3D strain measurements, contributing to further discrepancies between the 2. CONCLUSIONS: Mechanisms for discrepancies between 2D and 3D strain measurements in fetal echocardiography were identified, and inaccuracies associated with 2D strains were highlighted. Understanding of this mechanism is useful and important for future standardization of fetal cardiac strain measurements, which we propose to be important in view of large discrepancies in measured values in the literature.


Assuntos
Ecocardiografia Tridimensional , Humanos , Ecocardiografia Tridimensional/métodos , Ventrículos do Coração/diagnóstico por imagem , Ecocardiografia/métodos , Função Ventricular Esquerda , Feto , Reprodutibilidade dos Testes
17.
Ann Thorac Surg ; 116(1): 86-93, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36481325

RESUMO

BACKGROUND: Early postoperative catheterizations (EPOCs) within 6 weeks after a congenital heart surgical procedure can treat residual lesions and provide important clinical information. However, EPOCs are often assumed to impose additional risk on a vulnerable patient population. This study aimed to describe the EPOC population, evaluate procedural safety, compare EPOC patients with procedure-matched non-EPOC patients, and determine risk factors for poor outcomes using data from the Congenital Cardiac Catheterization Project on Outcomes registry. METHODS: In a retrospective cohort, demographic, clinical, and procedural characteristics were analyzed for diagnostic and interventional catheterizations performed in 13 participating institutions from January 2014 to December 2017, excluding patients after heart transplant. The primary outcome was a high-severity adverse event (AE). Three distinct analyses included (1) describing the full cohort and EPOC patients, (2) comparing EPOC patients with and without a high-severity AE, and (3) comparing EPOC patients with controls matched on case type. RESULTS: This study included 17,776 catheterizations, with 1399 EPOCs. The high-severity AE rate was 6.4% overall, 8.9% in the EPOC cohort, and 8.4% in matched controls (P = .74). The association between EPOC status and high-severity AE was not significant in a multivariable model (P = .17). In EPOCs with a high-severity AE, median procedure duration was 30 minutes longer (P < .001), and median time from surgical procedure to catheterization was 3 days longer (P = .05). CONCLUSIONS: EPOC was not associated with additional risk. Individual patient characteristics of size and hemodynamic vulnerability may serve as informative predictors. Timely catheterization may preempt further clinical deterioration, and intraprocedure duration optimization may correlate with improved outcomes.


Assuntos
Cardiopatias Congênitas , Humanos , Estudos Retrospectivos , Cardiopatias Congênitas/diagnóstico , Fatores de Risco , Cateterismo Cardíaco/efeitos adversos , Hemodinâmica
18.
Pediatr Cardiol ; 44(1): 132-140, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36029321

RESUMO

The aim of the study was to determine the variables associated with high-quality (HQ) versus low-quality (LQ) three-dimensional rotational angiography (3DRA) and create guides for optimization of approach to 3DRA in congenital cardiac catheterization (CCC). CCC has adopted 3DRA as a mainstay, but there has not been systematic analysis of approach to and factors associated with HQ 3DRA. This was a single-center, retrospective study of 3DRAs using Canon Infinix-I platform. Reconstructions were graded by 3 interventionalists. Quality was dichotomized into HQ and LQ. Univariable analyses and multivariable logistic regression models were performed. From 8/2016 to 12/2018, 208 3DRAs were performed in 195 CCCs; median age 7 years (2, 16), weight 23 kg (12, 57). The majority of 3DRAs were performed in patients with biventricular physiology (N = 137, 66%) and in pulsatile sites (N = 144, 69%). HQ 3DRA (N = 182, 88%) was associated with greater total injection volume [2.20 mL/kg (1.44, 3.29) vs. 1.62 mL/kg (1.10, 1.98), p = 0.005] and more dilute contrast solution [60% (50, 100) vs. 100% (60, 100), p = 0.007], but not with contrast volume administered (p = 0.2) on univariable analysis. On multivariable logistic regression, HQ 3DRA was significantly associated with patient weight [OR 0.97 (95% CI (0.94, 0.99), p = 0.018], total injection volume [OR 1.04 (95% CI 1.01, 1.07) p = 0.011], and percent contrast solution [OR 0.97 (95% CI 0.95, 1.00), p = 0.022]. These data resulted in creation of scatter plots and a novel 3DRA Nomogram for estimating the probability of HQ 3DRA. This is the first study to create evidence-based contrast dose guides and nomogram for 3DRA in CCC. HQ 3DRA was associated with lower weight, higher total injection volumes, and more dilute contrast solution.


Assuntos
Imageamento Tridimensional , Procedimentos de Cirurgia Plástica , Humanos , Criança , Estudos Retrospectivos , Imageamento Tridimensional/métodos , Angiografia/métodos , Cateterismo Cardíaco/métodos
19.
Extracell Vesicle ; 12022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36330420

RESUMO

Patients with single ventricle heart defects requires a series of staged open-heart procedures, termed Fontan palliation. However, while lifesaving, these operations are associated with significant morbidity and early mortality. The attendant complications are thought to arise in response to the abnormal hemodynamics induced by Fontan palliation, although the pathophysiology underlying these physicochemical changes in cardiovascular and other organs remain unknown. Here, we investigated the microRNA (miRNA) content in serum and serum-derived extracellular vesicles (EVs) by sequencing small RNAs from a physiologically relevant sheep model of the Fontan operation. The differential expression analysis identified the enriched miRNA clusters in (1) serum vs. serum-derived EVs and (2) pre-Fontan EVs vs. post-Fontan EVs. Metascape analysis showed that the overexpressed subset of EV miRNAs by Fontan procedure target liver-specific cells, underscoring a potentially important pathway involved in the liver dysfunction that occurs as a consequence of Fontan palliation. We also found that post-Fontan EV miRNAs were associated with senescence and cell death, whereas pre-Fontan EV miRNAs were associated with stem cell maintenance and epithelial-to-mesenchymal transition. This study shows great potential to identify novel circulating EV biomarkers from Fontan sheep serum that may be used for the diagnosis, prognosis, and therapeutics for patients that have undergone Fontan palliation.

20.
Commun Med (Lond) ; 2: 3, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35603301

RESUMO

Background: Tissue-engineered vascular grafts (TEVGs) have the potential to advance the surgical management of infants and children requiring congenital heart surgery by creating functional vascular conduits with growth capacity. Methods: Herein, we used an integrative computational-experimental approach to elucidate the natural history of neovessel formation in a large animal preclinical model; combining an in vitro accelerated degradation study with mechanical testing, large animal implantation studies with in vivo imaging and histology, and data-informed computational growth and remodeling models. Results: Our findings demonstrate that the structural integrity of the polymeric scaffold is lost over the first 26 weeks in vivo, while polymeric fragments persist for up to 52 weeks. Our models predict that early neotissue accumulation is driven primarily by inflammatory processes in response to the implanted polymeric scaffold, but that turnover becomes progressively mechano-mediated as the scaffold degrades. Using a lamb model, we confirm that early neotissue formation results primarily from the foreign body reaction induced by the scaffold, resulting in an early period of dynamic remodeling characterized by transient TEVG narrowing. As the scaffold degrades, mechano-mediated neotissue remodeling becomes dominant around 26 weeks. After the scaffold degrades completely, the resulting neovessel undergoes growth and remodeling that mimicks native vessel behavior, including biological growth capacity, further supported by fluid-structure interaction simulations providing detailed hemodynamic and wall stress information. Conclusions: These findings provide insights into TEVG remodeling, and have important implications for clinical use and future development of TEVGs for children with congenital heart disease.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA